This is the EP device implant registry case scenario for July of 2021, where we will review primary bradycardia indication present. This case scenario involves a 37-year-old female with a past medical history of morbid obesity of greater than 400 pounds, long-standing sleep apnea, and atrial fibrillation. Approximately one year ago, she underwent successful gastric bypass surgery with a weight loss greater than 150 pounds. The sleep apnea resolved with her significant weight loss. However, her atrial fibrillation remains permanent despite multiple cardiovergence. Today she presents for a leadless pacemaker due to periods of near syncope caused by tachycardia bradycardia syndrome, which was recently diagnosed. How is primary bradycardia indication present coded? Number one, no, or number two, yes? Please take a moment to review the documentation and question. And the correct answer is number two, yes. In this scenario, the patient received a leadless pacemaker for tachybradysyndrome. Primary bradycardia is indicating the patient's principal reason for receiving a device, which is the need for pacing. The option to submit novel pacemakers in version 2.3 are inclusive of any CRTPs, leadless pacemakers, or HIS, left bundle pacemakers. Thank you for viewing the EP device implant registry case scenario for July of 2021, which highlights the primary bradycardia indication present for novel permanent pacemakers.
Video Summary
In this video, the case scenario involves a 37-year-old female with a history of morbid obesity, sleep apnea, and atrial fibrillation. Despite successful weight loss surgery and resolution of sleep apnea, her atrial fibrillation persists. She is now presenting with near syncope caused by tachycardia bradycardia syndrome and is in need of a leadless pacemaker. The primary bradycardia indication for the patient is coded as "yes" because the need for pacing is the main reason for receiving the device. The video also mentions that the option to submit novel pacemakers includes various types such as CRTPs, leadless pacemakers, and HIS left bundle pacemakers. Credits were not mentioned in the transcript.
Keywords
atrial fibrillation
leadless pacemaker
weight loss surgery
sleep apnea
tachycardia bradycardia syndrome
×
Please select your language
1
English