Video Summary
The video discusses a case scenario in which a 79-year-old male receives a dual-chamber permanent pacemaker with a His lead implanted. The procedure involved cannulating the left axillary vein, inserting a short J-guide wire, and placing a sheath and His lead in the right ventricle and septum. Despite the lead being initially dislodged, it was successfully repositioned, and the pacing and sensing thresholds were acceptable. The patient was discharged following a clear chest X-ray. The video then poses two questions related to coding and metrics, with the answers being that the lead was successfully implanted and the patient is not included in the numerator for adverse events. No credits were provided.