false
Catalog
EPDIR-0422 - Sequence # 14739 | His / Left Bundle ...
0422 - Sequence # 14739 | His / Left Bundle Lead a ...
0422 - Sequence # 14739 | His / Left Bundle Lead and Metric 31
Back to course
[Please upgrade your browser to play this video content]
Video Transcription
Video Summary
The summary of the video is a case scenario review of Sequence 14-739, His Left Bundle Lead, and Metric 31 for the EP Device Implant Registry in April 2022. The video describes a 64-year-old female patient who received a dual-chamber ICD. The physician attempted His bundle area pacing but was unable to achieve true His pacing. The right atrial lead was successfully implanted with satisfactory sensing and pacing characteristics. The LV lead was not attempted to be placed. The patient's His Left Bundle Lead is coded as successfully implanted. The patient is not included in the numerator of metric number 31, which measures unsuccessful attempts to place a His Left Bundle Lead. Metric 31 is a negative metric.
Keywords
Sequence 14-739
His Left Bundle Lead
Metric 31
EP Device Implant Registry
dual-chamber ICD
×
Please select your language
1
English