Video Transcription
Sequence 13534, device capture and repositioning performed, would be coded as yes when any valve is repositioned even if the valve is manufactured to be repositioned. This data element is not seeking information for an adverse event, but is seeking to determine if any valve was repositioned during a transcatheter TAVR procedure. When a transcatheter valve is not repositioned during the case, sequence 13534 would be left blank and sequence 13535, device capture and repositioning performed, not applicable, would be captured. When the valve does not have the ability to be repositioned, such as a SAPIEN 3, please code not applicable.
Video Summary
In a transcatheter TAVR procedure, sequence 13534 is coded as "yes" if any valve is repositioned, regardless of whether it is designed to be repositioned or not. This data element is not related to adverse events, but simply determines if any valve was repositioned. If no valve is repositioned, sequence 13534 is left blank and sequence 13535, "device capture and repositioning performed, not applicable," is recorded. If the valve cannot be repositioned, like a SAPIEN 3, it is coded as "not applicable".