Video Summary
Sequence 13536 is about the successful implantation of a Transcatheter Aortic Valve Replacement Device and is a parent field. The retired Sequence 6235 has been replaced by Sequence 13536. It determines if the valve is correctly positioned. If the procedure converts to open heart surgery due to valve failure, it is coded as No. If the procedure converts to open heart surgery for a different complication, it is coded as Yes. Sequence 13539, a child field of Sequence 13536, determines the reason for unsuccessful device implantation with options of device embolization, improper device positioning, improper device sizing, and other reasons.
Keywords
Transcatheter Aortic Valve Replacement Device
implantation
valve positioning
open heart surgery
device embolization
×