false
Catalog
STSTVT-0421 - Sequence # 9002 | (Intra/Post-Proced ...
0421 - Sequence # 9002 | (Intra/Post-Procedure Ev ...
0421 - Sequence # 9002 | (Intra/Post-Procedure Events Occurred - Vascular Complication - Minor)
Back to course
[Please upgrade your browser to play this video content]
Video Transcription
Video Summary
In this video, the presenter discusses Sequence 9002, Intra-Post-Procedure Events Occurred, specifically focusing on a case involving a 74-year-old male who underwent TAVR. The right femoral valve delivery site was closed with a per-close closure device, but the sutures were suboptimal. Manual pressure was applied to achieve hemostasis, and there were no signs of complications such as extravasation, oozing, or hematoma. When coding for a minor vascular complication, the answer is "No" because there was no evidence of access site injury, closure device failure leading to major bleeding, distal embolization, or the need for vascular repair. The definitions used in this coding reference the standardized endpoint definitions for transcatheter aortic valve implantation published in 2012.
Keywords
Sequence 9002
Intra-Post-Procedure Events Occurred
TAVR
per-close closure device
minor vascular complication
×